Page blog ripple challenge en 1

Low Impedance HV Components are a Big Challenge When Ripple Testing

Published: 24th January 2022

Low impedance HV components are a big challenge when ripple testing

Ripple testing might seem to be like an easy to perform test – but the devil lies in the detail. The biggest challenge is how to reach the required ripple voltage levels at the EUT terminals. And this depends heavily on the impedance of the component.

High voltage components of the drive train (HV battery and inverters) are designed to provide the required energy to accelerate the car. The power is typically in the range of 50kW for small cars and can go up to 300kW for sports cars or even higher for heavy duty vehicles. They are designed for maximum performance and efficiency. Efficiency depends on internal losses, where thermal loss is the dominant factor. Thermal loss is given by the electrical losses P = I2R. In other words, the smaller the (internal) resistance of the component the better the efficiency.

For DC, the DC equivalent resistance is important. For ripple, the AC impedance is more important – seen over the full frequency range that needs to be tested. Here two typical impedance vs. frequency plots of HV components:

The battery shows a relatively flat impedance curve in the lower frequency range with impedance value in the range of 20 mΩ (very large battery) to 200 mΩ (for smaller hybrid batteries). The impedance increases with higher frequencies to several ohms.

Other components like inverters, chargers or DC-DC converters show a different impedance curve. The minimum at 6 kHz indicates a resonance frequency, which is caused by the input filter of the component. The frequency and steepness of the curve depends on the capacitors and inductors used in the filter. At resonance frequencies, the impedance reaches extremely small values in the mΩ range.

The challenge of the ripple test is seen when the low impedance and the required voltage amplitudes are combined using Ohm’s law:

FREQUENCY IMPEDANCE RIPPLE VOLTAGE RIPPLE CURRENT RIPPLE POWER
100 Hz 50 mΩ 24 Vpp 480 App (170 Arms) 1,44 kVA
10 kHz 70 mΩ 48 Vpp 685 App (242 Arms) 4.7 kVA
100 kHz 600 mΩ 16 Vpp 26 App (9 Arms) 0.05 kVA

This example shows that very high ripple currents and ripple power is required to reach the voltage levels defined by the standard. Caused by the fact that HV components have very small internal impedance.

It is not in all situations reasonable to test with the highest ripple currents since it might lead to the destruction of the component. Here it makes sense to limit the ripple currents to values that realistically can occur in the car.

MCS Test are an approved UK partner for Ametek CTS
Content Source: LOW IMPEDANCE | The ripple test challenge (ametek-cts.com)

You Might also like

Ripple Immunity Testing for the Next Generation of Electric Vehicles has just got easier!

Ripple Immunity Testing for the Next Generation of Electric Vehicles has just got easier!

AMETEK CTS is pleased to announce the release of the New Ripple NX, a high-power ripple generator designed to perform ripple immunity tests.

Read more
Evpost ripple en 1

What is Ripple and Where it Occurs

Ripple is a disturbance signal that is superimposed on a supply line. Typically, it originates from switching of power electronics i.e. MOSFETs or IGBTs. On an electric vehicle the biggest source for ripple is the electric propulsion system, namely the inverter part.

Read more
Page blog ripple challenge en 1

Low Impedance HV Components are a Big Challenge When Ripple Testing

Ripple testing might seem to be like an easy to perform test – but the devil lies in the detail. The biggest challenge is how to reach the required ripple voltage levels at the EUT terminals. And this depends heavily on the impedance of the component.

Read more

Sign up for the MCS Newsletter

You will receive all the latest test & measurement news and rental offers.