About Dips, Interrupts & Variations
High end single and multifunctional solutions for simulating Dips, Interrupts and Variations according to IEC/EN 61000-4-11 and IEC/EN 61000-4-29 standards.

AMETEK CTS TVT 1-250-16 Single Phase Tapped Transformer
Tapped transformer in a compact size
TVT 1-250-XX series - tapped transformers for testing voltage dips and interruptions Voltage dips and short interruptions simulate a reduction of the power supply voltage for a certain period of time. Four different test levels are required as per IEC/EN 61000-4-11.

AMETEK CTS TVT 1-250-16.1 Single Phase Tapped Transformer
Tapped transformer in a compact size
TVT 1-250-16.1 - tapped transformers for testing voltage dips and interruptions Voltage dips and short interruptions simulate a reduction of the power supply voltage for a certain period of time. Four different test levels are required as per IEC/EN 61000-4-11.

AMETEK CTS TVT 1-250-32 Single Phase Tapped Transformer
Tapped transformer in a compact size
TVT 1-250-32 - tapped transformers for testing voltage dips and interruptions Voltage dips and short interruptions simulate a reduction of the power supply voltage for a certain period of time. Four different test levels are required as per IEC/EN 61000-4-11.

EM Test MV 3P40100DS Motorised AC Variacs
3- phase Motorized Variac
The motorized AC variacs of the series MV are suitable for voltage dips and voltage variation test. The Motorvariac is suitable for testing 3-phase EUT in delta and star connection as per IEC 61000-4-11 Ed 2 : 2004-03.

EM Test MV 3P4016DS Motorised AC Variacs
3- phase Motorized Variac
The motorized AC variacs of the series MV are suitable for voltage dips and voltage variation test. The Motorvariac is suitable for testing 3-phase EUT in delta and star connection as per IEC 61000-4-11 Ed 2 : 2004-03.

EM Test MV 3P4032DS Motorised AC Variacs
3- phase Motorized Variac
The motorized AC variacs of the series MV are suitable for voltage dips and voltage variation test. The Motorvariac is suitable for testing 3-phase EUT in delta and star connection as per IEC 61000-4-11 Ed 2 : 2004-03.

EM Test MV 3P4063DS Motorized AC Variacs
3- phase Motorized Variac
The motorized AC variacs of the series MV are suitable for voltage dips and voltage variation test. The Motorvariac is suitable for testing 3-phase EUT in delta and star connection as per IEC 61000-4-11 Ed 2 : 2004-03.

EM Test MV 3P4832DS Motorised AC Variacs
3- Phase Motorized Variac
The motorized AC variacs of the series MV are suitable for voltage dips and voltage variation test. The Motorvariac is suitable for testing 3-phase EUT in delta and star connection as per IEC 61000-4-11 Ed 2 : 2004-03.

EM Test MV 3P69100DS Motorised AC Variacs
3- phase Motorized Variac
The motorized AC variacs of the series MV are suitable for voltage dips and voltage variation test. The Motorvariac is suitable for testing 3-phase EUT in delta and star connection as per IEC 61000-4-11 Ed 2 : 2004-03.

EM TEST NX1-260-16 Single Phase Motor Variac
Voltage range: 0 up to 260 V
The variac NX1-260-16 is a single phase motor variac that allows to steplessly adjust the EUT supply voltage from 0V to 260 V when supplied by a 230 V mains supply voltage.

EM Test NX1-260-32 Single Phase Motor Variac
Voltage range: 0 up to 260 V
The variac NX1-260-32 is a single phase motor variac that allows to steplessly adjust the EUT supply voltage from 0V to 260 V when supplied by a 230 V mains supply voltage.

EM Test NX1-280-16 Single Phase Motor Variac
Voltage range: 0 up to 280 V
The variac NX1-280-16 is a single phase motor variac that allows to steplessly adjust the EUT supply voltage from 0V to 260 V when supplied by a 230 V mains supply voltage.

EM Test PFS 503N Series Power Fail Simulator
Standalone test generator for dips, short interruptions and voltage variation
Unlike any other Power Fail simulator the EM TEST PFS 503N Series represents a real three-phase Power Fail simulator. Not only phase-by-phase testing is possible but any combination of phases and all three phases can be simultaneously tested. Herefore the PFS503N Series is equipped with six individually controlled semiconductor switches. Each switch is electronically short-circuit protected.

EM Test PFS 503Nx.2 Series Power Fail Simulator
Standalone test generator for dips, short interruptions and voltage variation
Unlike any other Power Fail simulator the EM TEST PFS 503N Series represents a real three-phase Power Fail simulator. Not only phase-by-phase testing is possible but any combination of phases and all three phases can be simultaneously tested. Herefore the PFS503N Series is equipped with six individually controlled semiconductor switches.