RF Probes and Clamps

RF Probes and Clamps

About RF Probes and Clamps

Absorbing Clamps are used for measuring interference signals on power supply cables. Decoupling clamps and ferrite tube are available for a variety of different EMC applications. The current sensing probes are used for current monitoring applications, such as those required by the BCI standards.


Keyword Search
category.title

Com-Power CLA-050 Absorbing Clamp

Frequency Range: 30 MHz - 1 GHz

The Com-Power CLA-050 Absorbing Clamp is designed as per CISPR 16-1-3: “Radio disturbance and immunity measuring apparatus – Ancillary equipment – Disturbance power” to measure disturbance power on power input lines as well as other auxiliary I/O lines.

category.title

Com-Power CLA-150 Absorbing Clamp

Frequency Range: 30 MHz - 1 GHz

The Com-Power CLA-150 measures radio noise power generated and fed through the power cables of these products above 30 MHz. It has a 32 mm cable aperture.

category.title

Com-Power CLCE-400 Current Probe

Frequency Range: 10 kHz - 400 MHz

The Com-Power CLCE-400 RF Current Probe is part of Com-Power's extensive line of radio frequency conducted emission/ immunity test equipment and calibration accessories.

category.title

Com-Power CLCI-100 Current Injection Probe

Frequency Range: 10 kHz - 100 MHz

The CLCI-100 Bulk Current Injection Probe is part of ComPower's extensive line of radio frequency conducted immunity test equipment and calibration accessories; geared specifically to comply with the requirements contained in IEC 61000-4-6 and CISPR 16-1-2.

category.title

Com-Power CLCI-400 Current Injection Probe

Frequency Range: 10 kHz - 400 MHz

The CLCI-100 Bulk Current Injection Probe is part of Com-Power's extensive line of radio frequency conducted immunity test equipment and calibration accessories; geared specifically to comply with the requirements contained in RTA/DO-160F, Mil-Std-461.

category.title

Com-Power PS-400 Near Field Sniffer Probes

Frequency Range: 9 kHz - 5 GHz

The Com-Power PS-400 Near Field Probe Set with a frequency range up to 5 GHz and has a impedance of 50 Ohm.

category.title

Com-Power PS-500 Near Field Probe Set

Frequency Range: 9 kHz - 5 GHz

The Com-Power PS-500 Near Field Probe Set with contact tip and a frequency range from 400 Hz - 5 GHz and a 50 Ohm Impedance.

category.title

Teseq CAL 801A Calibration Fixture

Length: 670 mm, 4 mm banana connectors on clamp side

CAL 801A calibration unit for KEMZ 801

category.title

Teseq CAL CMAD20A Calibration Fixture

Calibration fixture for CMAD 20A, CMAD 20B, Lüthi FTC 40x15 E according CISPR 16-1-4

Calibration fixture for CMAD 20A, CMAD 20B, Lüthi FTC 40x15 E according CISPR 16-1-4 The through-reflect-line (TRL) calibration method is recommended for measuring the S-parameters of CMADs, as described in CISPR 16-1-4.

category.title

Teseq CAL KEMZ Calibration Fixture

Fixture for S-parameter measurement of KEMZ 801, KEMZ 801A, KEMA 801, KEMA 801A

Calibration fixture for KEMZ/KEMA 801 IEC 61000-4-6 (EN 61000-4-6) defines three basic types of transducer used for the injection of test signals into the equipment under test (EUT).

category.title

Teseq CIP 9136A Probe

Wide frequency range 4 kHz - 400 MHz

The CIP 9136 probe has been manufactured to drawings and specifications laid down by QinetiQ. It meets the requirements for HIRF testing where conventional ferrite core material cannot handle the higher powers required (up to 1000 W), without changing characteristics when heated.

category.title

Teseq CIP 9138 Probe

Frequency range from 4 kHz to 200 (400) MHz

The CIP 9138 probe has been designed for MIL-STD-461G CS114 with the extended range from 4 kHz to 1 MHz for EUTs intended to be installed on ships or submarines.

category.title

Teseq CMAD 10 Common Mode Absorption Device

Frequency range 1 MHz to 1 GHz

The CMAD 10 improves the asymmetrical line termination in the frequency range above 1 MHz and improves measurement reproducibility. The CMAD needs to be clipped on lines leaving the test chamber or GTEM cell. The CMAD 10 is designed to accept cable sizes of up to 10 mm and was developed for CISPR 22 Edition 4.0 2003.

category.title

Teseq CMAD 20B Absorption Device

Frequency range 1 MHz to 1 GHz

The CMAD (Common Mode Absorption Device) is specified in CISPR 16-1-4 and its use is defined in CISPR 16-2-3 and CISPR 11 edition 6.0. It improves the asymmetrical line termination in the frequency range 30 MHz to 200 MHz and improves measurement reproducibility.

category.title

Teseq CSP 9160A Probe

Suitable for emission measurements per CISPR 16-2-1, CISPR 22 and CISPR 32

The CSP 9160 is a broadband RF current sensor probe as defined in CISPR 16-1-2. Beside the compliance measurements of asymmetrical disturbance currents as e.g. required in CISPR 16-2-1 and CISPR 22, the probe can be used in a number of diagnostic applications to measure superimposed RF currents flowing in conductors, or cable harnesses.

category.title

Teseq CVP 2200A Probe

CISPR 22 (EN 55022), CISPR 32 (EN 55032) and CISPR 16-1-2 compliant

The Capacitive Voltage Probe (CVP) is designed for measuring asymmetrical disturbances on cables with capacitive coupling principle. It gives the opportunity to do the measuring without disconnection of the tested cable (“in-situ”) and it avoids the influence of the transmission.

category.title

Teseq FT 801 Ferrite Tube

Excellent decoupling from 150 kHz

The FT 801 is recommended as an additional decoupling network (ferrite tube) for immunity test according to IEC / EN 61000-4-6 when using the clamp injection method.

category.title

Teseq KEMA 801B RF Attenuation Clamp

High decoupling, Suitable to KEMZ 801

The KEMA 801B replaces KEMA 801A and is recommended as an additional decoupling network (ferrite tube clamp) for immunity test according to IEC/EN 61000-4-6 when using the clamp injection method.

category.title

Teseq KEMZ 801A EM Clamp

As specified in IEC/EN 61000-4-6

IEC 61000-4-6 (EN 61000-4-6) defines three basic types of transducer used for the injection of test signals into the equipment under test (EUT).

category.title

Teseq MBT 2 ( f.MDS21) Slide Lane For Disturbance Power Measuring

Hand-operated slide lane for absorbing clamps

The MBT 2 is a hand-operated slide lane for absorbing clamp MDS 21B. It consists of the slide lane, a table for the EUT and a drive unit. The drive unit enables the tester to move the MDS 21B manually along the lane.

Pagination

Sign up for the MCS Newsletter

You will receive all the latest test & measurement news and rental offers.