- Description
- Specifications
- Documents
Formally branded Teseq MDS-21B, now incorporated into Ametec CTS range
In connection with a measuring receiver according to CISPR 16-1-1, the absorbing clamp MDS enables to measure the interference capability of radio interferers, such as domestic appliances, electric tools etc. directly; viz. by measuring the power generated by the interferer and fed to its supply cable. The absorbing clamp measurement method (ACMM) is described in Clause 7 of CISPR 16-2-2: Specification for radio disturbance and immunity measuring apparatus and methods – Part 2-2: Methods of measurement of disturbances and immunity – Measurement of disturbance power. The absorbing clamp itself is described in CISPR 16-1-3: Radio disturbance and immunity measuring apparatus – Ancillary equipment – Disturbance power.
- As specified in CISPR 16-1-3/EN 55016-1-3
- Disturbance power measuring, according to CISPR 16-2-2/EN 55016-2-2, CISPR 13/EN 55013, CISPR 14-1/EN 55014-1 and EN 50083-2
- Excellent for using as diagnostic tool and for measurements of screening attenuation of coaxial cables
- Supplied with 6 dB attenuator and RF cable