RF System Components and Accessories

RF System Components and Accessories

About RF System Components and Accessories

Specially designed system components for EMC testing requirements featuring a large dynamic range, fast measurement devices, rugged design and a frequency range that matches the application. The system components can be purchased as individual parts or as a full configured system defined by the user for frequency and power requirements.


Keyword Search
category.title

Single Band CBA6G D Series Amplifier

Class A Operation, 100% Mismatch Tolerant with no Foldback

Class A, high power density, design has allowed us to produce a 1.0 GHz to 6 GHz amplifier series with power levels from 30 to 400 watts P1dB. These amplifiers are ideal for RF immunity testing in a GTEM Cell or with a wide range of available horn antenna such as the Teseq BHA range or readily integrated with an NSG 6000 to form part of a broadband RF test system.

category.title

Teseq ATN 6 Series Attenuators

60 W / 150 W / 200 W, DC to 1 GHz

6 dB- 50 Ω attenuators, particularly for minimising reflection losses in tests per IEC/EN 61000-4-6 also useful for general purposes.

category.title

Teseq BAA 6001 Tube for DPA

Insertion loss: up to 0.8 dB @ 3 GHz

Antenna tube, recommended for RSG 1000 and RSG 3000 mounted on BTP 6020 and CHA 9425A

category.title

Teseq BTP 6010 Tripod

Tripod for RSG 1000 and RSG 3000

Tripod for RSG 1000 and RSG 3000. Combined with BAA 6001 and BAA 6010 tripod for DPA 3000 and DPA 4000.

category.title

Teseq BTP 6020 EMC Antenna Tripod

Easy height adjustment and transportability

The BTP 6020 collapsible tripod has been designed for indoor radiated emission an immunity testing; using Teseq antennas with 22 mm diameter tube mounts like CBL 6111, 6112, 6141 and 6143.

category.title

Teseq CAS BAL4070 Calibration Set

Designed for function tests, verification measurements and / or calibration on BAL 4070

The product CAS BAL4070 is made for function tests, verification measurements and / or calibration on BAL 4070. Measuring parameter is the coupling attenuation S21.

category.title

Teseq CBA250M-2500 Amplifier

Class A Operation, Ideal for Low Frequency Tests Using Strip Line Devices

This low frequency amplifier can be used in conjunction with other amplifiers from the Teseq range to cover the entire frequency range from 10 kHz to 40 GHz with convenient frequency break points allowing you to optimise the power level in each range.

category.title

Teseq CBA250M-800-002 Amplifier

Designed specifically for conducted EMC testing

Designed specifically for conducted EMC testing, this mismatch tolerant Class A amplifier is ideally suited for automotive test applications.

category.title

Teseq CFL 9206A Transient Limiter

Helps to protect spectrum and measuring receivers from damage

The CFL has been designed to interface between a transducer (antenna, line network) and measuring equipment (receiver, spectrum analyzer).

category.title

Teseq CIS EMC Laboratory Control Software

Sophisticated, easy to use and fully featured RF EMC software package

Compliance Immunity Software (CIS) is a sophisticated EMC laboratory control software designed to make RF Immunity testing fast, efficient, compliant, accurate and simple. A major feature in CIS is the availability of ‘Installable Applications’.

category.title

Teseq CTP 6099 Antenna Tripod

Easy height adjustment and transportability

The CTP 6099 tripod is ideal for outdoor applications and use on soft ground. It has been designed for the loop antenna HLA 6120 and can be used with the optionally available adapters for other antennas

category.title

Teseq DCP 0100A Dual Directional Coupler

Dual directional coupler, Wide frequency range, High power handling

This high power dual directional coupler has been specifically designed for EMC immunity applications.

category.title

Teseq Isolation Transformer (ITF) 60 dB

Isolation transformer 60 dB, Meets the requirements of IEC/EN 61000-4-16

ITF 6A, ITF 14A, ITF 22, Isolation Transformer 60 dB. The Isolation Transformer (ITF) provides the 60 dB decoupling as required in IEC / EN 61000-4-16.

category.title

Teseq KSQ 1000A Spherical Reference Radiation Source

Up to 60 dBuV/m in a 10 m measuring distance

Compact spherical reference radiation source for the transfer of ‘Interference Field Strength’ value, offers very good price-performance relation. The KSQ 1000 is a special version of reference radiation source for the frequency range 30 MHz to 1 GHz.

category.title

Teseq LE 4031 Artificial Network

Designed for IEC / EN 61000-4-31, NSG 4031 and CDND M316-16

The LE 4031 provides the RF cables, attenuators, baluns and termination as needed for the level setting procedure in accordance with the standard IEC / EN 61000-4-31.

category.title

Teseq LNA 6000 Low Noise Amplifier

Wide band, Low noise figure

The LNA 6000 is a low noise amplifier with 12.5 dB of gain covering the nominal frequency range 1 MHz to 3 GHz and can be used in the range from 200 kHz to 4 GHz.

category.title

Teseq LNA 6900 Low Noise Amplifier

Ultra wide band, High gain, Low noise figure

The LNA 6900 is a low noise amplifier with 25 dB of gain covering the nominal frequency range 9 kHz to 2 GHz and can be used up to 4 GHz.

category.title

Teseq LNA 6901 Low Noise Amplifier

Wide band, High gain, Low noise figure

The LNA 6901 is a low noise amplifier with typ. 28 dB of gain covering the nominal frequency range 9 kHz to 1 GHz and can be used up to 2 GHz.

category.title

Teseq PMR 6003 Power Meter

Frequency range 9 kHz to 3 GHz

EMC immunity testing makes very specific demands on RF power meters. A large dynamic range, fast measurements, rugged design and a frequency range that matches the application are some of the unique requirements for power meters in an EMC test environment.

category.title

Teseq PMR 6006

Frequency range 1 MHz to 6 GHz

EMC immunity testing makes very specific demands on RF power meters. A large dynamic range, fast measurements, rugged design and a frequency range that matches the application are some of the unique requirements for power meters in an EMC test environment.

Pagination

Sign up for the MCS Newsletter

You will receive all the latest test & measurement news and rental offers.