Oscilloscope Probes & Accessories

Oscilloscope Probes & Accessories

About Oscilloscope Probes & Accessories

To further exploit the range of tests available to electrical test engineers, lab technicians or automotive engineers, there are accessories available including probes and probe sets, adaptor plugs, break-out adaptors, and spare battery packs for hand-held models.


Keyword Search
Select a Measurement
category.title

Keysight 10073D 500 MHz Passive Probe

Bandwidth: 500 MHz, System risetime (calculated): <700 ps

Keysight 10073D passive probe is their most rugged 500 MHz probe.

Find out more about Keysight 10073D 500 MHz Passive Probe
category.title

Keysight 1146B AC / DC Current Probe, 100 kHz, 100 A

Working voltage: 600 V max, Frequency range: DC to 100 kHz (-3dB with current de-rating)

The 1146B is ideal for capturing transient current signals such as those found in motor controllers, switching power supplies, inverters and current amplifiers driving inductive loads.

Find out more about Keysight 1146B AC / DC Current Probe, 100 kHz, 100 A
category.title

Keysight 1147B AC/DC Current Probe, 50 MHz, 15A

Wide bandwidth: DC to 50MHz, High S/N Ratio

The 1147B is ideal for capturing transient current signals such as those found in motor controllers, switching power supplies, inverters and current amplifiers driving inductive loads.

Find out more about Keysight 1147B AC/DC Current Probe, 50 MHz, 15A
category.title

Keysight DSOX2000-805 LAN/VGA Module InfiniiVision 2000 & 3000 X-Series Oscilloscope

Combines 10/100Mbit LAN port with VGA out, Module plugs into rear-panel expansion slot

LAN/VGA module for the InfiniiVision 2000 and 3000 X-Series Oscilloscope (MSOX2000-805, DSOX3000-805).

Find out more about Keysight DSOX2000-805 LAN/VGA Module InfiniiVision 2000 & 3000 X-Series Oscilloscope
category.title

Keysight N2781B AC / DC Current Probe, 10 MHz, 150 Arms

Take accurate measurements with a hybrid technology

The N2781B current probe is an accurate and reliable solution for measuring AC and DC currents. Using a hybrid technology that includes a Hall effect sensor and an AC current transformer, the probe provides accurate measurement of DC or AC currents up to 150 Arms continuous

Find out more about Keysight N2781B AC / DC Current Probe, 10 MHz, 150 Arms
category.title

Keysight N2782B AC / DC Current Probe, 50 MHz, 30 Arms

AC / DC Current Probe, 50 MHz, 30 Arms

Compatible with any oscilloscope with high impedance BNC input, the N2782B current probe offers accurate and reliable solution for measuring ac and dc currents. Using a hybrid technology that includes a Hall effect sensor and an AC current transformer, the probe provides accurate measurement of DC or AC currents up to 30 Arms continuous.

Find out more about Keysight N2782B AC / DC Current Probe, 50 MHz, 30 Arms
category.title

Keysight N2790A High-Voltage Differential Probe, 100 MHz

User-selectable attenuation settings of 50:1 or 500:1

Use the N2790A 100-MHz high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope.

Find out more about Keysight N2790A High-Voltage Differential Probe, 100 MHz
category.title

Keysight N2791A High-Voltage Differential Probe, 25 MHz

25 MHz bandwidth, User-selectable attenuation settings of 10:1 or 100:1

Use the N2791A 25-MHz low-cost high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope.

Find out more about Keysight N2791A High-Voltage Differential Probe, 25 MHz
category.title

Keysight N2843A Passive Probe, 10:1, 500 MHz, 1.2 m

Passive probe - 500 MHz 10

Keysight N2843A low-cost passive probe provides a 10:1 attenuation and features a high input resistance of 10 MΩ. The probe can be adjusted for low-frequency compensation and high-frequency compensation.

Find out more about Keysight N2843A Passive Probe, 10:1, 500 MHz, 1.2 m
category.title

Keysight N2873A Passive Probe, 10:1, 500 MHz, 1.3 m

500 MHz bandwidth, 10:1 attenuation ratio

The N2873A passive probe offers DC to 500 MHz and 10:1 attenuation factor to address a wide range of measurement needs.

Find out more about Keysight N2873A Passive Probe, 10:1, 500 MHz, 1.3 m
category.title

Keysight N2874A Passive Probe, 10:1, 1.5 GHz, 1.3 m

1.5 GHz bandwidth, 10:1 attenuation ratio

The N2874A passive probe offers DC to 1.5 GHz and 10:1 attenuation factor to address a wide range of measurement needs.

Find out more about Keysight N2874A Passive Probe, 10:1, 1.5 GHz, 1.3 m
category.title

Keysight N2889A Passive Probe, 10:1/1:1, 350 MHz, 1.3m

Bandwidth: DC to 350MHz (@10:1), DC to 10MHz (@1:1), Risetime: 1 nsec (@10:1), 35 nsec (@1:1) (10%-90%)

The N2889A provides a switch in the probe handle that allows to choose the attenuation ratio between 1:1 and 10:1.

Find out more about Keysight N2889A Passive Probe, 10:1/1:1, 350 MHz, 1.3m
category.title

Keysight N2893A AC/DC Current Probe, 100 MHz, 15A

Remove any residual magnetism and unwanted DC offset

The Keysight N2893A is a 100 MHz bandwidth, active current probe for InfiniiVision and Infiniium oscilloscopes. The probe features flat bandwidth (DC-100MHz), low noise(<2.5 mA rms) and low circuit insertion loss. Auto demagnetization (degauss) and calibration removes any residual magnetism and unwanted DC offset in the probe. The probe is powered directly by the InfiniiVision and Infiniium Autoprobe interface, eliminating the need for an additional power supply.

Find out more about Keysight N2893A AC/DC Current Probe, 100 MHz, 15A
category.title

Keysight N2894A Passive Probe, 10:1, 700MHz, 1.3m

Passive probe - 700 MHz

The N2894A passive probe offers DC to 700 MHz and 10:1 attenuation factor to address a wide range of measurement needs.

Compact 2.5-mm probe head diameter, low input capacitance, and various fine-pitch probe tip accessories make the Keysight N2894A Series passive probes ideal for probing densely populated IC components or surface-mount devices used in today's high-speed digital applications.

Find out more about Keysight N2894A Passive Probe, 10:1, 700MHz, 1.3m
category.title

Keysight N7020A Power Rail Probe, 2 GHz

Power Rail Probe

The N7020A power rail probe is for users making power integrity measurements that need mV sensitivity when measuring noise, ripple and transients on their DC power rails. The probe is designed for measuring periodic and random disturbances (PARD), static and dynamic load response, programmable power rail response and similar power integrity measurements.

Find out more about Keysight N7020A Power Rail Probe, 2 GHz
category.title

Keysight N7026A AC/DC High Sensitivity Clamp-On Current Probe, 150 MHz

AC/DC high sensitivity current probe, 150MHz

Keysight N7026A is a 150 MHz bandwidth, active current probe for InfiniiVision and Infiniium oscilloscopes. The probe features wide and flat bandwidth (DC-150 MHz), lower noise (<250 µArms), and wide input range (up to continuous 30Arms or non-continuous 40Apeak). This enables you to measure down to 1 mA/div, giving you a much more accurate view of your low-level signals.

Find out more about Keysight N7026A AC/DC High Sensitivity Clamp-On Current Probe, 150 MHz
category.title

Tektronix A621 Current Probe

50 kHz Bandwidth

The A621 can measure AC currents from 100 mA to 2000 A peak over a frequency range of 5 Hz to 50 kHz. It provides a 1 mV, 10 mV, or 100 mV output for each Amp measured.

Find out more about Tektronix A621 Current Probe
category.title

Tektronix A622 Current Probe

Bandwidth: 100 kHz

The A622 can measure AC/DC currents from 50 mA to 100 A peak over a frequency range of DC to 100 kHz. It provides 10 mV or 100 mV output for each Amp measured.

Find out more about Tektronix A622 Current Probe
category.title

Tektronix ADA400A Differential Preamplifier

Bandwidth: 1 MHz

The ADA400A Differential Preamplifier allows direct oscilloscope measurements of very low amplitude voltages and signals which are not ground referenced.

Find out more about Tektronix ADA400A Differential Preamplifier
category.title

Tektronix CT2 Current Probe

200 kHz Bandwidth, Rise Time: < 500 ps

The A621 can measure AC currents from 100 mA to 2000 A peak over a frequency range of 5 Hz to 50 kHz. It provides a 1 mV, 10 mV, or 100 mV output for each Amp measured.

Find out more about Tektronix CT2 Current Probe

Pagination

Sign up for the MCS Newsletter

You will receive all the latest test & measurement news and rental offers.